Automobile Accessories Manuals. Automobile Parts Manuals. Beverage Dispenser Manuals. Blower Manuals. Boiler Manuals. Bread Maker Manuals. Brush Cutter Manuals. Burner Manuals. Carpet Cleaner Manuals. Chainsaw Manuals. Charcoal Grill Manuals. Clothes Dryer Manuals. Coffeemaker Manuals. Computer Drive Manuals. Convection Oven Manuals. Cooktop Manuals. Cookware Manuals.
Corded Headset Manuals. Cordless Drill Manuals. Dehumidifier Manuals. Dishwasher Manuals. Double Oven Manuals. DVD Recorder Manuals. Egg Cooker Manuals.
Electric Grill Manuals. Electric Pressure Cooker Manuals. Electric Steamer Manuals. Electronic Accessory Manuals. Serial number breakdown.
W B 5 1 8 0 4 2 4 7 Incremented unit number Production week Last digit of production year Product identification Manufacturing Facility 3. Electrical Specifications Refer to serial name plate. Temperature Control 7. Operating the using this freezer. Such damage is not covered under the For Your Safety warranty.
Distribute packages to be frozen evenly throughout If needed, add metal or wood shims between feet pads the freezer. Page Care And Cleaning other packages in the freezer, slide the basket aside or of the cabinet and remove.
Reverse this procedure to lift out. Do not touch interior metal surfaces with wet or damp hands. Page Moving Clean and dry the interior thoroughly. To prevent odor and mold growth, leave the freezer lid open slightly, block- ing it open if necessary.
Moving: Disconnect the power cord plug from the wall outlet. Remove foods and clean the freezer. Secure all loose items, such as baskets, by taping them securely in place to prevent damage. It may save you both time and expense.
This list includes common occurrences that are not the result of defective workmanship or materials in this appliance. Turn the control to a colder setting. Allow several hours for the temperature to stabilize. Warm air enters the freezer every time the lid is opened. This is normal. Open the Lid less often. B Are not occasioned by either the manual disconnection of the electrical power within the premises of the owner or a general power failure.
The fin and tube evaporator is mounted to the left side of the of the freezer compartment. Page The Defrost Circuit defrost timer is in the run mode contacts 1 to 4 At a predetermined condition, the run winding are closed and powers applied to the overload current, which is also the current through the relay protector of the compressor.
Current flows through coil, drops to a value below that necessary to hold the overload protector applying powers to both up the relay armature. Page Defrost Timer Motor Circuit 3. Defrost Timer Motor Circuit. The defrost timer motor circuit is made up of the cold control and the defrost timer motor. Whenever the cold control contacts are closed.
Power is applied to the defrost timer motor. This means that the defrost timer motor only runs whenever the cold control contacts are closed. Persons attempting to use these to make but potential hazard, never add repairs to the sealed refrigeration system should refrigerant to a seal system. Page Refrigeration System 7. Allow the joint to cool then wash exterior with water 4. The capillary tube connects the output end of the drier to remove flux.
Refrigeration System Basic components of a freezer are: 1. The compressor located in the machine compartment. Page Refrigerant Cycle Note: Portions of the capillary tube and the with no refrigeration. Suction pressure will drop below suction line are solder together to form the atmospheric pressure, and air and moisture will be drawn heat exchanger.
Refrigerant Cycle If a slight undercharge of refrigerant is indicated, and no leak could be found after a thorough leak test, the charge Page Evacuating And Recharging 4. Connect a pressure gauge and access valve to the compounds in standard refrigeration discharge tube and pressurize to lbs.
Leak test low-side. Close compound gauge. Run compressor for a few minutes and leak test high side. Page Final Leak Test 9. When satisfied that the unit is operating correctly, clamp the high-side process tube with the pinch-off tool while the unit is still running.
Slowly open the high-side manifold gauge valve to allow the compressor to remove any refrigerant trapped in the high-side hose and the process fitting. Clause-Remedy 1. No voltage at wall receptacle - check circuit breaker Compressor Will Not Run. Service cord pulled out of the wall receptacle - replace.
Low voltage causing compressor to cycle on overload. Erratic control thermostat, or setting too cold - replace are reset to normal position. Freezer exposed to unusual heat - relocate freezer. Abnormally high room temperature - advised customer. Freezer Too Warm. Inoperative fan motor - check wiring and fan motor. Improperly positioned fan blade - position blade at end of shaft. Evaporator iced up - check defrost system. Defrost heater in operative - check wiring and defrost heater. Disconnect electrical power from the freezer.
Unless stated, reverse the procedure to reinstall the component.